Sterilization Effects on Liposomes with Varying Lipid Chains
- Back
Metadata
Document Title
Sterilization Effects on Liposomes with Varying Lipid Chains
Author
Cherdchom S.
Name from Authors Collection
Affiliations
Center of Excellence in Preventive and Integrative Medicine (CE-PIM), Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand; Department of Preventive and Social Medicine, School of Global Health, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand; Bumrungrad International Hospital, Bangkok, 10110, Thailand; Department of Infection Biology & Microbiomes, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, L69 7ZX, United Kingdom; National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Ministry of Higher Education, Science, Research and Innovation, 111 Thailand Science Park, Phahonyothin Road, Klong Nueng, Klong Luang, Pathum Thani, 12120, Thailand; Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand; Center of Excellence in Nanomedicine, Department of Anatomy, Faculty of Medicine, Chulalongkorn University, 1873 Rama 4 Road, Pathumwan, Bangkok, 10330, Thailand
Type
Article
Source Title
Nanomaterials
ISSN
20794991
Year
2025
Volume
15
Issue
19
Open Access
All Open Access; Gold Open Access; Green Open Access
Publisher
Multidisciplinary Digital Publishing Institute (MDPI)
DOI
10.3390/nano15191478
Abstract
Liposomes, nanoscale vesicles with distinct structural and functional properties, are widely utilized in drug delivery due to their biocompatibility and ability to encapsulate diverse therapeutic agents. Effective sterilization is essential to ensure the safety and efficacy of liposomal formulations in biomedical applications, yet its impact on liposome integrity and functionality remains inadequately studied. This work systematically evaluates the effects of three sterilization methods: autoclaving, UV radiation, and filtration—on liposomes composed of dipalmitoylphosphatidylcholine (DPPC) and distearoylphosphatidylcholine (DSPC), two phospholipids differing in lipid chain length. Sterilization altered liposome properties in a lipid chain length-dependent manner, affecting particle size, zeta potential, and phospholipid content. Filtration caused significant hydrocarbon loss, confirmed by Fourier-transform infrared spectroscopy (FTIR) and Raman spectroscopy, and led to a higher reduction in phospholipid content in DPPC liposomes compared to DSPC liposomes. Biological evaluations showed that autoclaved and UV-irradiated DPPC liposomes exhibited higher cytotoxic and lower stability than their DSPC counterparts. While autoclaving and UV irradiation resulted in minimal chemical alterations, both methods significantly influenced biological properties. Filtration, although less disruptive to biocompatibility, also reduced key liposomal integrity and efficacy. This study underscores the critical importance of post-sterilization evaluation to optimize liposomal formulations for clinical and biomedical use. © 2025 by the authors.
License
CC BY
Rights
Authors
Publication Source
Scopus