-
LAMP using distance based paper device for quantitative detection of ESBL producing Escherichia coli in UTI patients
- Back
Metadata
Document Title
LAMP using distance based paper device for quantitative detection of ESBL producing Escherichia coli in UTI patients
Name from Authors Collection
Scopus Author ID
57221437108
Scopus Author ID
16028140700
Affiliations
Analytical Chemistry, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Bangkok, 10140, Thailand; BIOTEC, National Science and Technology Development Agency (NSTDA), Pathum Thani, 12120, Thailand; Department of Parasitology, Phramongkutklao College of Medicine, Bangkok, 10400, Thailand; Department of Parasitology, Faculty of Medicine, Kasetsart University, Bangkok, 10900, Thailand; Division of Microbiology, Department of Clinical Pathology, Phramongkutklao Hospital, Bangkok, 10400, Thailand; Office of Research and Development, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand; Department of Microbiology, Phramongkutklao College of Medicine, Bangkok, 10400, Thailand
Type
Article
Source Title
Scientific Reports
ISSN
20452322
Year
2025
Volume
15
Issue
1
Open Access
All Open Access; Gold Open Access; Green Open Access
Publisher
Nature Research
DOI
10.1038/s41598-025-21371-1
Abstract
Extended-spectrum beta-lactamases (ESBLs) producing E. coli are the most critical cause of antimicrobial resistance (AMR) and multidrug resistance (MDR) producing prolonged hospitalization and burden in treating nosocomial infection, in which the conventional culture regularly constitutes the gold standard diagnosis. In this study, we developed and validated a simple and inexpensive distance-based paper device (dPAD) LAMP assay for simultaneous screening and semi-quantifying the resistant bacterial load of ESBL-producing E. coli in 427 urine samples of patients with urinary tract infection (UTI). The device could measure the LAMP amplicons of blaTEM gene and semi-quantify the degree of ESBL-producing E. coli in heavy (≥ 102 CFU/mL), light (101–102 CFU/mL) and none ( 48 h) and cheaper than qPCR. To empower early AMR diagnosis and fast treatment of MDR, this inexpensive dPAD LAMP assay is simple, reliably fast and practically portable for point-of-care settings, particularly in resource-limited areas that can be set up in all levels of healthcare facilities. © The Author(s) 2025.
Keyword
ESBL | Escherichia coli | LAMP | Paper device | Quantitative | SYBR safe | Urine | UTI
License
CC BY-NC-ND
Rights
Authors
Publication Source
Scopus
Publication Source
Scopus